Course: Electrical Workshop Practice I &II
1. Internal InstallationPractice
The laboratory exercise includes:
- Splicing
- One lamp controlled from two differentplaces
- Series Circuit and ParallelCircuit
- Two Lamps Controlled from Four Differentplaces
- Master ON/OFFcircuit
- Wiring of FluorescentLamp
- Bell Circuit and AnnunciatorCircuit
2. Induction Motor Control
Induction Motor Control Training System – Lab Volt (Qty - 02)
- Direct online
- Forward–Reverse
- Sequential operation ofmotor
- Star -Delta
Coil Winding Machine (Qty -03) Rewinding of contactorcoil
4. Designing and Winding of Single-PhaseTransformer
a. Single phase core typetransformer
b. Single phase shell typetransformer
5. Induction motorrewinding
Course: Electrical Machines
Laboratory equipment’s list and descriptions
Electrical Machines Lab contains following machines and equipment. This lab caters to courses such as Introduction to Electrical Machine and Advanced Electrical Machine.
1. Single phase and three phasetransformers
|
|
|
Single-Phase Transformer DL 1093 (Qty 2)
| Single-Phase Transformer DL 1093 (Qty 2)
| Single-Phase Transformer DL 1093 (Qty 2)
|
Three-Phase Transformer DL 1080 (Qty 2)
| Three-Phase Transformer DL 1080 (Qty 2)
| Three-Phase Transformer DL 1080 (Qty 2)
|
Feedback Three Phase Transformer 61-307 (Qty 2)
| Feedback Three Phase Transformer 61-307 (Qty 2)
| Feedback Three Phase Transformer 61-307 (Qty 2)
|
Transformer parallel operation kit DL2009
| Transformer parallel operation kit DL2009 | Transformer parallel operation kit DL2009 |
The experiments that can be performed are:
- Measuring WindingResistance
- Measuring TransformationRatio
- Determination of thePolarities
- No-Load and Short CircuitTests
- Transformer paralleloperation
2. Three phase inductionmachines
|
|
Squirrel Cage Three-Phase Asynchronous Motor DL 2050 (Qty 2)
| Squirrel Cage Three-Phase Asynchronous Motor DL 2050 (Qty 2)
|
Slip Ring Three-Phase Asynchronous Motor DL 2053A (Qty 2)
| Slip Ring Three-Phase Asynchronous Motor DL 2053A (Qty 2)
|
The experiments that can be performed are:
- Stator Winding Resistancemeasuring
- No LoadTest
- Blocked RotorTest
- Testing on Three Phase Slip Ring InductionMotor
- Starting of squirrel cage and wound rotor inductionmotor
3. Dcmachines
MV1006 DC-Machine (Qty 8)
The machine has a shunt and a series winding and can be connected as shunt motor, series motor, compound motor, shunt generator,
series generator or compound generator. MV 1006 has also commutating poles (interpoles) which improve the characteristics of the
machine. The machineis mounted on a 10 mm thick anodized aluminum plate to be placed on the machinebed.
| General Data | MV1006-225 | MV1006-226 |
Generator | 1.2 kW 1400 rpm | 1.2 kW 1700 rpm | |
Shunt motor | 1.0 kW 1400 rpm | 1.0 kW 1700 rpm | |
Series motor | 1.0 kW 1150 rpm | 1.0 kW 1400 rpm | |
Rotor | 220 V 5.5 A | 220 V 5.5 A | |
Excitation | 220 V 0.55 A | 220 V 0.55 A | |
The series winding has an extra terminal at 2/3 of the winding. | |||
Moment of inertia | J = 0.012 kgm2 (approx.) | ||
Dimensions | 465 x 300 x 310 mm Shaft height 162 mm | ||
Weight | 45 kg | ||
| Accessories: | Suitable shunt rheostat: MV1905. |
MV1028 DC Machine (Qty 2)
Complete with interpoles. This machine is used in test machine sets such as motors or generators, mounted on a 10 mm thick
anodized Aluminum plate to be placed on the machine bed MV 1004.